Stair Calculator
Enter the floor-to-floor rise and pick a code. Get the number of risers, the exact riser height, the total run, the angle and a mark-out list, checked against the IBC, IRC, Wisconsin dwelling code or OSHA.
Equal risers, checked against the code.
Results update as you type. Inches take whole numbers, decimals or fractions, such as 9, 9.5 or 9 1/2.
Risers are equal. Every code here allows only 3/8 inch between the largest and smallest riser or tread in a flight as built (OSHA asks for uniform steps without a number), so lay out from these marks, not by stacking one step on the last.
OTHER RISER COUNTS
LAYOUT MARKS
Measure the real rise, then lay out once.
Finished floor to finished floor
Measure the rise to the finished surfaces. A floor covering or topping added later changes the bottom and top risers and can put them out of tolerance.
More risers, gentler stair
Adding a riser makes each step shorter and the run longer. The table of other riser counts shows the trade so you can fit the stair to the space.
Mark from the floor
The layout marks give each tread height from the bottom floor and each nosing from the bottom riser face, rounded from the exact layout. Marks taken from one end do not stack up error.
Which code, and what it says.
| Limit | IBC 2021 | IRC 2021 | Wisconsin UDC | OSHA 1910.25 |
|---|---|---|---|---|
| Riser | 7 in max, 4 in min (1011.5.2) | 7 3/4 in max (R311.7.5.1) | 8 in max (SPS 321.04(2)(b)) | 9 1/2 in max (1910.25(c)(2)) |
| Tread | 11 in min (1011.5.2) | 10 in min (R311.7.5.2) | 9 in min (SPS 321.04(2)(c)) | 9 1/2 in min (1910.25(c)(3)) |
| Angle | — | — | — | 30° to 50° (1910.25(c)(1)) |
| Rise of one flight | 12 ft max (1011.8) | 151 in max (R311.7.3) | Landing needed at 12 ft or more (SPS 321.04(4)(a)) | not stated |
| Headroom | 80 in (1011.3) | 6 ft 8 in (R311.7.2) | 76 in (SPS 321.04(2)(d)) | 6 ft 8 in (1910.25(b)(2)) |
| Width | 44 in; 36 in under 50 occupants (1011.2) | 36 in (R311.7.1) | 36 in (SPS 321.04(2)(a)) | 22 in (1910.25(c)(4)) |
| Handrail height | 34 to 38 in (1014.2) | 34 to 38 in (R311.7.8.1) | 30 to 38 in (SPS 321.04(3)(b)) | 30 to 38 in (1910.29(f)(1)) |
| Riser and tread variation | 3/8 in in a flight (1011.5.4) | 3/8 in (R311.7.5) | 3/8 in (SPS 321.04(2)(e)) | uniform (1910.25(b)(3)) |
The IBC also lets stairs inside a dwelling unit (Group R-3, and inside units of R-2) use a 7 3/4-inch riser and 10-inch tread with a nosing; pick IRC for those numbers. Wisconsin adopted the 2021 IBC for commercial buildings effective September 1, 2025 (SPS 361.05), and its amendments do not change riser or tread sizes. OSHA applies to workplace stairs in general industry; ship stairs, spiral stairs and alternating tread devices have their own limits not covered here.
“2R + T” under the angle is a comfort check, not a code rule. A common target is about 25 inches (U.S. Army course EN5156, Carpentry II).
Layout aid only. This tool lays out risers and treads. It does not design stringers, connections, landings, guards or handrails, and local amendments or your inspector have the final word. Need a steel stair built? Ask us for a quote.
Talk to Our Team
Our specialists are happy to answer your questions and help scope your project.